Productdetails
Productnaam:
Geofysisch Exploratieinstrument
Gebruik:
ondergrondse wateropsporing
Het meten van Voltagewaaier:
±40V 32 A/D
Het meten van voltageresolutie:
5nV
Het meten van voltagenauwkeurigheid:
Voltage >1mV, nauwkeurigheid ≤0.1%, voltage ≤1mV, accuracy±1uV
OEM/ODM:
Ja
Het meten van het stroombereik:
0 -6000 mA (32 A/D)
Het meten van huidige resolutie:
10nA
Het meten van huidige nauwkeurigheid:
Wanneer Ip≥10mA, ±0.1%, wanneer Ip<10mA, nauwkeurigheid ±2uA
Markeren: 

Grout seal integrity viewer

,

Geophysical exploration cam

,

Packer setting confirmation tool

Productomschrijving

Environmental site assessments demand defensible data. The DZD-8 Multi-function Full Wave DC Electron Meter delivers repeatable resistivity and IP measurements that stand up to regulatory review. Whether you are mapping a contaminant plume, locating a landfill boundary, or imaging a saltwater intrusion, this instrument provides the evidence you need.

Why full waveform recording matters for environmental work. Traditional meters average signals, hiding transient noise from nearby pumps, traffic, or telluric currents. The DZD-8 records 1KHz waveforms of both current and potential. You can visually inspect each measurement. If noise is present, you see it. You can also recalculate polarizability using different delay times – a critical feature when the secondary field from clay or organic contamination is weak.

Accuracy specifications ensure defensible reporting. Voltage resolution 5nV, accuracy ≤0.1% for signals >1mV. Current resolution 10nA. Apparent polarizability error ≤±0.2%. These specs exceed typical environmental requirements. When a regulator asks about data quality, you can point to these numbers.

The instrument measures parameters that characterize contamination.

  • Resistivity distinguishes clean sand/gravel (high) from clay or leachate (low).

  • Polarizability (IP) responds to clay minerals, organic matter, and some metal contaminants.

  • Self-potential detects groundwater flow and redox zones.

  • Metal factor and attenuation provide additional discrimination.
    All from one measurement sequence.

Field workflow for a typical site assessment.

  1. Lay out a 2D ERT line across the suspected plume. Use centralized or distributed cables.

  2. Press “Res” to check ground resistance. Fix any poor electrodes (water or reposition).

  3. Create a new project: name it, select 2D ERT, set electrode spacing and layout.

  4. Press “Measure”. The DZD-8 automatically sequences through electrode pairs.

  5. The screen builds a pseudo-section in real time.

  6. After survey, press “7” to check data quality. Retest any questionable points with “9”.

  7. Transfer data via USB to the included software.

Rolling measurement extends profiles without moving all electrodes. After completing one section, the system prompts you to move a subset of cables. You can survey hundreds of meters with a single cable set – efficient for long pipelines or shoreline assessments.

3D ERT for detailed source zone imaging. Use S, U, W, or Wang cable layouts. The instrument handles up to 60 or more electrodes depending on configuration. The 3D preprocessor lets you edit data, delete bad electrodes, and export to inversion software. The final 3D model can be contoured in GIS or CAD.

Data security and chain of custody. All raw waveforms are saved on the internal SD card (16G to 64G optional). USB transfer is simple – the instrument appears as a drive. No proprietary formats that require expensive software to read. The provided analysis software exports to ASCII, Res2Dinv, Res3Dinv, and Surfer. Keep the raw files as your audit trail.

The instrument is rugged for industrial sites. IP67 waterproof – hose it off after a dirty survey. Working temperature -20°C to +60°C. The 6.4 inch high-brightness LCD is readable in direct sun. The enclosure withstands vibration from trucks and generators.

Power options for long days. Internal 16.8V 12.5Ah battery lasts 20 hours. For multi-day assessments, bring a 12V external battery and connect via the charge port. The instrument displays remaining charge as a percentage. Below 15%, the screen shows orange – time to plug in.

Transmitter capabilities for conductive environments. Maximum 1400V and 6A, 7500W output. In urban settings with low ground resistance, you may need only 50-100V. But for resistive dry sand or gravel, higher voltage pushes current through. Pulse width adjustable from 1 to 64 seconds – longer pulses improve signal-to-noise for deep or noisy sites.

Troubleshooting common field issues – environmental edition.

  • High VP error: Usually means low voltage (<1mV). Increase MN spacing or use longer pulse.

  • Current too low: Dry ground. Water the A/B electrodes or add multiple stakes per pole.

  • Current output protection: AB short circuit or very low ground resistance. Reduce voltage.

  • Erratic readings: Look for nearby power lines or cathodic protection systems. Move line perpendicular to interference source.
    The manual includes a four-resistor test (1kΩ, 100Ω, 1kΩ in series) to verify instrument channels. Perform this test before each major project.

Software for data review and reporting. The “Multifunctional DC analysis software” allows:

 

 

Grout Seal Integrity Viewer Packer Setting Confirmation Cam 0

 

Grout Seal Integrity Viewer Packer Setting Confirmation Cam 1

 

Grout Seal Integrity Viewer Packer Setting Confirmation Cam 2

  • Project creation with custom pole tables.

  • Coordinate modification (start coordinates, point spacing).

  • Polarizability secondary extraction – change integration windows after field work.

  • Data export in multiple formats.

  • File merging for combined profiles.
    No subscription fees – buy once, use forever.

Parameter Table

 
 
Parameter DZD-8 Specification
Receiver Full waveform record of current and potential
Voltage range ±40V, 32-bit A/D
Voltage resolution 5nV
Voltage accuracy >1mV: ≤0.1%; ≤1mV: ±1uV
Apparent polarizability acc. Fs error ≤±0.2%
Current range 0 – 6000 mA, 32-bit A/D
Current resolution 10nA
Current accuracy ≥10mA: ±0.1%; <10mA: ±2uA
Sampling frequency 1KHz
Input impedance ≥50MΩ
50Hz interference suppression >120dB
SP compensation ±40V full range real-time auto digital tracking
Max supply voltage 1400V
Max supply current 6A
Max output power 7500W
Power pulse width 1-64s, duty cycle 1:1
Operating system Embedded Linux real-time
Display 6.4 inch, 24-bit color, 1200cd/m2 brightness
Data storage 16G-64G optional, USB2.0 transfer
Internal battery 16.8V 12.5Ah, works 20 hours
External battery 12V
Waterproof IP67
Working temperature -20 to +60°C, 95% RH
Size 300 x 225 x 132 mm
Weight 5.6 kg

In the box: Main unit, USB cable, high voltage input cable, external battery cable, charger, non-polarized electrodes (1 pair), stainless steel electrodes (10 pieces), USB drive, manual, certification, warranty card. Everything you need for environmental geophysics.

For environmental consultants, the DZD-8 reduces risk. You get verifiable full waveform data, high accuracy, rugged durability, and transparent software. Deliver reports with confidence.

Grout Seal Integrity Viewer Packer Setting Confirmation Cam 3

Grout Seal Integrity Viewer Packer Setting Confirmation Cam 4

Grout Seal Integrity Viewer Packer Setting Confirmation Cam 5

Contacteer op elk ogenblik ons

0086-159-2263-6015
1F Technical Building, Longxin Industrial Park, district Nan'an, Chongqing China
Rechtstreeks uw onderzoek naar verzend ons